Fire Performances of Partially Encased column subjected to Eccentric Loading Conference Paper uri icon

abstract

  • In this paper, the advanced and simplified calculation methods are used to evaluate the fire resistance of eccentrically loaded partially encased composite columns (PEC).
  • In this paper, the advanced and simplified calculation methods are used to evaluate the fire resistance of eccentrically loaded partially encased composite columns (PEC). The work consists in developing an efficient Non-linear 3-D finite element model (ANSYS) to investigate the behaviour of Pin-ended PEC eccentrically loaded at elevated temperature. The columns were tested under standard ISO834 fire. The buckling load is determined for several column heights 3; 4.5 and 6 m, by considering an eccentricity around the minor axis equal to 0,5.B ; 1,0.B and 1,5.B (B base). The numerical method presented here is compared with the simple calculation method Annex G of EN 1994-1-2. The results show that after 50 min of fire exposure, the axial load capacity of PEC is reduced to more than half, which is a fair conclusion to take into consideration in structural fire design. The comparison results show a good agreement between the two methods at high fire ratings (R90 and R120), however at low fire rating (R30), the simple calculation method presents conservative results. It is to be concluded that the eccentricity of loading reduces the loadbearing capacity of the composite column. The shortest column (3m) presents the higher reduction in load bearing.

publication date

  • April 2019